Welcome to Journal of Graphics

Journal of Graphics ›› 2026, Vol. 47 ›› Issue (5): 1033-1042.DOI: 10.11996/JG.j.2095-302X.2026051033

Previous Articles     Next Articles

A multi-stage CT-MRI registration method for spine based on multi-vertebra structural modeling

YANG Zhiyong1, LIU Di1, JIANG Shan1, ZHOU Zeyang1, HAN Jun2, ZHU Shan2, CHEN Chao2()   

  1. 1 School of Mechanical Engineering, Tianjin University, Tianjin 300350, China
    2 Tianjin Hospital, Tianjin University, Tianjin 300211, China
  • Received:2026-05-11 Accepted:2026-07-31 Online:2026-10-31 Published:2026-10-26
  • Supported by:
    Tianjin Municipal Education Commission Scientific Research Project(2023YXZD11)

Abstract:

In minimally invasive spinal surgery, a single imaging modality cannot simultaneously provide sufficient information on both osseous structures and soft tissues, making intraoperative spatial localization challenging. Conventional cross-modality registration methods often struggle to accommodate the intensity differences between CT and MRI, inconsistent scan coverage, imaging artifacts, and the distinct motion characteristics of multiple spinal tissues, which may lead to registration failure and vertebral localization errors. To address these issues, a multi-stage spinal CT-MRI registration method based on multi-vertebra structural modeling was proposed. In the coarse registration stage, anatomical constraints were constructed using vertebral segmentation results. Common vertebral labels were extracted from the two modalities, and a representative vertebra was selected as an anchor to initialize rigid and affine transformations, thereby reducing large-scale pose differences and preventing non-rigid registration from becoming trapped in local optima. In the fine registration stage, a deep neural network integrating multi-vertebra affine modeling and diffeomorphic deformation was developed. The multi-vertebra affine branch characterized the approximately rigid motion of different vertebral segments, while velocity-field integration was employed to generate a diffeomorphic deformation field for modeling the nonlinear deformation of intervertebral discs and surrounding soft tissues, thereby achieving high-precision non-rigid registration. Experiments were conducted on a self-built spinal CT-MRI dataset. The proposed method achieved Dice, HD95, and ASD values of 91.43%, 2.61 mm, and 1.16 mm, respectively, in the lumbar region, outperforming all comparison methods. Quantitative results demonstrated that the proposed method improved the regional overlap and boundary alignment accuracy of lumbar vertebral structures. The visualization results further demonstrated that it could effectively coordinate the local near-rigid motion of vertebral segments with the continuous deformation of surrounding tissues, maintaining good stability and anatomical rationality. This provided a technical foundation for preoperative multimodal image fusion and subsequent surgical navigation.

Key words: spine, multimodal registration, CT-MRI, deep learning, diffeomorphic registration

CLC Number: